Tripp Lite / Eaton PDUMH30HV19NET switched/network rackmount PDU.This is a high-voltage datacenter/server PDU with network management, outlet switching, front load metering, and mixed IEC C13/C19 outlets. Suitable for server racks, homelab, datacenter equipment, lab equipment, networking gear, and other 208V/230V rack power applications.Specifications:
- Brand: Tripp Lite / Eaton
- Model: PDUMH30HV19NET
- Input: 208/230V, 24A, 50/60Hz, single-phase
- Plug: NEMA L6-30P
- Outlets: 8x IEC C13 + 6x IEC C19
- Total outlets: 14
- Form factor: 2U rackmount
- Switched / network-managed PDU
- Front load meter/display
- Bank 1 / Bank 2 output breakers
- Ethernet/network port
- USB/config port
- Serial config portIncluded:
- Tripp Lite PDUMH30HV19NET PDU with attached L6-30P power cord
- Original Tripp Lite box with foam packaging
- Rackmount ears/brackets
- Cord-retention clips
- Screw pack
- Configuration cableCondition:
Used datacenter/server PDU. Physical condition is good overall with normal cosmetic marks from rack/server use. Please review all photos for exact condition and included accessories.Testing performed:
- Unit powers on successfully
- Front display illuminates
- Outlet status LEDs illuminate
- Network/status indicators illuminate
- Web management interface was reachable after factory reset
- Default localadmin login was accepted
- PowerAlert management interface loaded normally
- Status/details page showed device present, normal output source, 233.5V input/output reading, 59.9Hz frequency, 2 circuits, and 1-phase operation
- About page showed PowerAlert driver/console/engine version 15.5.6 Build 2002 and normal driver file statusThe unit will be factory reset again before shipping.Important:
This is not a standard household 120V power bar. This unit requires 208V/230V service and a compatible NEMA L6-30R receptacle. Please confirm compatibility with your electrical setup before purchasing.Protection note:
This model has overload protection via output circuit breakers. It is not being advertised as a surge-protection PDU.Photo privacy note:
MAC address and serial number have been digitally obscured/blurred in some photos and web interface screenshots for privacy/security. The smudges/blurred areas are edits to the photos only and are not marks, damage, stickers, or residue on the actual unit.Testing limitation:
This unit was pulled from a live working environment and has been power-on tested with the web management interface confirmed reachable. Full individual outlet switching and all advanced network management features were not separately tested after removal.Shipping:
Ships in the original Tripp Lite box with foam packaging.