UBB Store

2PCS G1/2 Meter LCD Digital Liquid Flowmeter For Diesel Gasoline 5‑600L/H
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
2PCS G1/2 Meter LCD Digital Liquid Flowmeter For Diesel Gasoline 5‑600L/H
Price: CN $51.11


2. Reliable Material: The flowmeter is made of nylon material, pressure resistance and wear resistance. The sealing ring is subjected to force up and down to ensure no leakage. The imported Hall prevents aging.
3. LCD Digital Display: This liquid meter adopts a high definition LCD display screen, providing clear and intuitive readings, and convenient adjustment, greatly improving detection efficiency.
4. G1/2in Meter: This gear flowmeter has standard G1/2 inch interface, providing stable and reliable connection. The working temperature range is ≤ 80℃, and the allowable pressure resistance is ≤1.75mpa.
5. Application Fields: Including 2 liquid meters, widely applied in fuel dispensers, beer machines, water fertilizer integrated machines, household water purifiers, and other liquid control class=\"wang-edit-text\">

Item Type: Digital Meter
Material: Nylon
Battery Type: 3 x AAA Battery (Not Included)
Product Model: LCD-05OFZAT
Interface Size: G1/2in
Usage Temperature Range: ≤80℃
Load Capacity: ≤10mA (DC5V)
Allowable Pressure Resistance: ≤1.75mpa
Storage Temperature Humidity: -25-80℃, 25%-90%RH
Range: 5-600L/H (Over Water Detection)
Pulse Characteristics: (Hz)=(2.5*Q)±5%, i.e. 150 Pulses Per Liter of Water
Output Pulse Duty Cycle: 50±10%
Digital Display Meter Parameter:
Applicable Medium: Most Pure and Stable Liquids (No Impurities, No Erosion Liquids)
Measuring Accuracy: ±5%
Repeatability: ±0.5%
Maximum Working Pressure: 20BAR
Standby Time: 1 Year
Single Count: 0.00-9999
Total Cumulative Count: 0-999999
Measurement Unit: L, GAL, PTS, m³
Single Metering Zero Clear: CAL
1. Clear Single Count
Press CLEAR key when counting or in standby mode, LCD full screen display, release CLEAR key to return to standby interface, and single count is cleared
2. Clear Total Accumulation
When counting or in standby mode, short press SETUP key to change to total accumulation display, short press CLEAR key to clear single count, then long press CLEAR key (more than 5s), after 5 seconds LCD screen will automatically return to standby interface, and total accumulation is cleared
3. Switch Display between Rate and Total Accumulation
When counting or in standby mode, short press SETUP key to switch between rate and total accumulation display
4. Pulse Setting
When counting or in standby mode, long press SETUP key (more than 5s) to enter coefficient setting interface, digit flicker can be set, short press CLEAR key to modify the value of flicker digit, short press SETUP key to switch the flicker digit, after setting is complete long press SETUP key or wait for 30 seconds to exit coefficient setting and save the setting value; the current value is 1000, indicating 1000 pulses corresponds to 1L
5. Unit Setting
During counting or standby state, long press SETUP + CLEAR key (more than 5s) to enter the unit setting screen, then press CLEAR key to switch units, after the setting is complete, long press SETUP key or wait 30 seconds to exit coefficient setting and save the setting
6. Quick Check Pulse Count and Total Accumulation
Counting or standby state, long press the SETUP + CLEAR key (less than 5 seconds), then display the total count since the pulse and product power(non clear List:

2 x Digital Meter


Note:

When the battery voltage is too low, the battery sign will appear on the LCD display, reminding the user to replace the battery. Too short battery life can cause damage to the flowmeter due to battery leakage during use. This flowmeter is designed for a standby life of about 2 years, but it is recommended that the customer replace the battery based on actual usage. The longer the daily usage time, the shorter the battery life. It is recommended that the customer check the battery terminals every six months. If there is rust, it should be removed in time. If the flowmeter has not been used for a long time, the battery should be removed. Avoid rain and sun exposure when using outdoors.



1. Our listing price includes the value of goods,packaging cost,and exporttaxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3.The duties are buyers\' responsibility.Please check with your country\'scustoms office determine what these additional costs will be prior to yourpurchase.
4. All disputes arising from the duties will be submitted to for solution.

1. Any questions,pls. contact us via message or email us.We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.

2. If you are satisfied with our service, pls. kindly leave us a positive response and give us the Detailed Seller Rating with all \"5\" in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better.We strive to keep all our customers satisfy.


We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.




Buy Now