Listing Grid template example Product Photo Description BROCADE VDX 6740 BR-VDX6740-24-F80-1007295-03 48-Port 10GbE SFP+4x 40GbE Switch
Up for sale is a BROCADE VDX 6740 BR-VDX6740-24-F80-1007295-03 48-Port 10GbE SFP+4x 40GbE Switch . This item has been TESTED, POWERED ON, FACTORY RESET, and all ports and lights are shown to be FULLY FUNCTIONAL. This item is in GOOD physical CONDITION with minor scratches, scrapes, and scuffs from previous usage and item DOES NOT come with a POWER CABLE. NO OTHER accessories are included with this item. Please refer to listing's pictures for more details.
You get exactly what you see in the pictures. Please see the pictures for more details.
The best descriptions are in the pictures. Please see the pictures for a better understanding of the item's do our best to describe each item. If you have any questions, feel free to contact us prior to making a purchase.
Please contact us if you have any issues with your purchase before leaving a review. We try our best to resolve all show Operating System Software
Network Operating System Version: 4.1.3
Copyright (c) 1995-2014 Brocade Communications Systems, Inc.
Firmware name: 4.1.3b
Build Time: 23:54:42 Apr 9, 2015
Install Time: 19:37:14 May 19, 2015
Kernel: 1.0.1
Control Processor: e500mc with 4096 MB of memory
Appl Primary/Secondary 4.1.3b
show Name: BR-VDX6740
switchType: 131
FAN Unit: 1
Time Awake: 0 days
FAN Unit: 2
Time Awake: 0 days
POWER SUPPLY Unit: 1
Factory Part Num: 23-1000043-01
Factory Serial Num:
Time Awake: 0 days
POWER SUPPLY Unit: 2
Factory Part Num: 23-1000043-01
Factory Serial Num:
Time Awake: 0 Unit: 1
Power Consume Factor: 0
Factory Part Num: 40-1000927-06
Factory Serial Num: CPL3806L05L
Manufacture: Day: 18 Month: 12 Year: 14
Update: Day: 28 Month: 12 Year: 2016
Time Alive: 580 days
Time Awake: 0 days
Airflow direction : Port side show cipherset
RADIUS Cipher is not configured
LDAP Cipher is not configured
SSH Cipher is not show cli
autowizard false
complete-on-space false
history 100
idle-timeout 600
ignore-leading-space false
output-file terminal
paginate true
prompt1 \H\M#
prompt2 \H(\m)#
screen-length 24
screen-width 80
service prompt config true
show-defaults false
terminal show dot1x
802.1X Port-Based Authentication: Disabled
PAE Capability: Authenticator Only
Protocol Version: 2
Auth Server: RADIUS
Readiness test timeout: show version history
Sno Date & Time Switch Name Slot PID OS Version
1 Tue May 19 19:35:28 2015 VDX2 0 1752 4.1.3b
2 Thu Feb 5 13:17:54 2015 sw0 0 1817 show Tue May 19 19:33:17 2015
Slot SWITCH/0: Firmware install begins.
[2]: Tue May 19 19:37:47 2015
Slot SWITCH/0: Firmware install ends.
[3]: Tue May 19 19:37:47 2015
Slot SWITCH/0: Firmware starts to swap.
[4]: Tue May 19 19:37:59 2015
Slot SWITCH/0: Firmware is Tue May 19 19:37:59 2015
Slot SWITCH/0: The blade begins to reboot.
[6]: Tue May 19 19:42:55 2015
Slot SWITCH/0: Firmware commit begins.
[7]: Tue May 19 19:44:38 2015
Slot SWITCH/0: Firmware commit ends.
[8]: Tue May 19 19:44:38 2015
Slot SWITCH/0: Firmware is downloaded show global-running-config
no fsb enable
logging raslog console INFO
logging auditlog class SECURITY
logging auditlog class CONFIGURATION
logging auditlog class FIRMWARE
logging syslog-facility local LOG_LOCAL7
logging syslog-client localip MM_IP
no support autoupload enable
support ffdc
snmp-server contact "Field Support."
snmp-server location "End User Premise."
snmp-server sys-descr "Brocade VDX Switch."
snmp-server community community OrigEquipMfr rw
snmp-server community "Secret C0de" rw
snmp-server community common
snmp-server community private rw
snmp-server community public
snmp-server user snmpadmin1 groupname snmpadmin
snmp-server user snmpadmin2 groupname snmpadmin
snmp-server user snmpadmin3 groupname snmpadmin
snmp-server user snmpuser1
snmp-server user snmpuser2
snmp-server user snmpuser3
line vty
exec-timeout 10
!
zoning enabled-configuration cfg-name ""
zoning enabled-configuration default-zone-access allaccess
zoning enabled-configuration cfg-action cfg-save
role name admin desc Administrator
role name user desc User
aaa authentication login local
aaa accounting exec default start-stop none
aaa accounting commands default start-stop none
service admin password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role admin desc Administrator
username user password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role user desc User
cee-map default
precedence 1
priority-group-table 1 weight 40 pfc on
priority-group-table 15.0 pfc off
priority-group-table 15.1 pfc off
priority-group-table 15.2 pfc off
priority-group-table 15.3 pfc off
priority-group-table 15.4 pfc off
priority-group-table 15.5 pfc off
priority-group-table 15.6 pfc off
priority-group-table 15.7 pfc off
priority-group-table 2 weight 60 pfc off
priority-table 2 2 2 1 2 2 2 15.0
remap fabric-priority priority 0
remap lossless-priority priority default
vlan 1002
priority 3
virtual-fabric 128
fcmap 0E:FC:00
max-enodes 0
enodes-config local
advertisement interval 8000
keep-alive timeout
!
map default
fabric-map default
cee-map Vlan 1
!
protocol lldp
advertise Brocade-VDX-VCS 100
!
vlan dot1q tag native
port-profile switchport
switchport mode trunk
switchport trunk allowed vlan switchport
switchport mode trunk
switchport trunk native-vlan default
port-profile show interface Status Mode Speed Type 2/0/49 sfpAbsent -- -- --
Fo 2/0/50 sfpAbsent -- -- --
Fo 2/0/51 sfpAbsent -- -- --
Fo 2/0/52 sfpAbsent -- -- --
Te 2/0/1 sfpAbsent -- -- --
Te 2/0/2 sfpAbsent -- -- --
Te 2/0/3 sfpAbsent -- -- --
Te 2/0/4 sfpAbsent -- -- --
Te 2/0/5 sfpAbsent -- -- --
Te 2/0/6 sfpAbsent -- -- --
Te 2/0/7 sfpAbsent -- -- --
Te 2/0/8 sfpAbsent -- -- --
Te 2/0/9 sfpAbsent -- -- --
Te 2/0/10 sfpAbsent -- -- --
Te 2/0/11 sfpAbsent -- -- --
Te 2/0/12 sfpAbsent -- -- --
Te 2/0/13 sfpAbsent -- -- --
Te 2/0/14 sfpAbsent -- -- --
Te 2/0/15 sfpAbsent -- -- --
Te 2/0/16 sfpAbsent -- -- --
Te 2/0/17 sfpAbsent -- -- --
Te 2/0/18 sfpAbsent -- -- --
Te 2/0/19 sfpAbsent -- -- --
Te 2/0/20 sfpAbsent -- -- --
Te 2/0/21 sfpAbsent -- -- --
Te 2/0/22 sfpAbsent -- -- --
Te 2/0/23 sfpAbsent -- -- --
Te 2/0/24 sfpAbsent -- -- --
Te 2/0/25 sfpAbsent -- -- --
Te 2/0/26 sfpAbsent -- -- --
Te 2/0/27 sfpAbsent -- -- --
Te 2/0/28 sfpAbsent -- -- --
Te 2/0/29 sfpAbsent -- -- --
Te 2/0/30 sfpAbsent -- -- --
Te 2/0/31 sfpAbsent -- -- --
Te 2/0/32 sfpAbsent -- -- --
Te 2/0/33 sfpAbsent -- -- --
Te 2/0/34 sfpAbsent -- -- --
Te 2/0/35 sfpAbsent -- -- --
Te 2/0/36 sfpAbsent -- -- --
Te 2/0/37 sfpAbsent -- -- --
Te 2/0/38 sfpAbsent -- -- --
Te 2/0/39 sfpAbsent -- -- --
Te 2/0/40 sfpAbsent -- -- --
Te 2/0/41 sfpAbsent -- -- --
Te 2/0/42 sfpAbsent -- -- --
Te 2/0/43 sfpAbsent -- -- --
Te 2/0/44 sfpAbsent -- -- --
Te 2/0/45 sfpAbsent -- -- --
Te 2/0/46 sfpAbsent -- -- --
Te 2/0/47 sfpAbsent -- -- --
Te 2/0/48 sfpAbsent -- -- show 1 DESCR:Chassis Fan module
PN:N/A 2 DESCR:Chassis Fan module
PN:N/A SUPPLY 1 DESCR:Chassis PS module
PN:23-1000043-01 SUPPLY 2 DESCR:Chassis PS module
PN:23-1000043-01 SN:N/A
NAME: Chassis DESCR:System Chassis
SID:BR-VDX6740 show 10G Port Upgrade license
License has expired
Feature name:PORT_10G_UPGRADE
LICENSE IS INVALID
Capacity: 40G Port Upgrade license
License has expired
Feature name:PORT_40G_UPGRADE
LICENSE IS INVALID
Capacity: show local-running-config
diag post rbridge-id 2/0/1
!
dpod 2/0/2
!
dpod 2/0/3
!
dpod 2/0/4
!
dpod 2/0/5
!
dpod 2/0/6
!
dpod 2/0/7
!
dpod 2/0/8
!
dpod 2/0/9
!
dpod 2/0/10
!
dpod 2/0/11
!
dpod 2/0/12
!
dpod 2/0/13
!
dpod 2/0/14
!
dpod 2/0/15
!
dpod 2/0/16
!
dpod 2/0/17
!
dpod 2/0/18
!
dpod 2/0/19
!
dpod 2/0/20
!
dpod 2/0/21
!
dpod 2/0/22
!
dpod 2/0/23
!
dpod 2/0/24
!
dpod 2/0/25
!
dpod 2/0/26
!
dpod 2/0/27
!
dpod 2/0/28
!
dpod 2/0/29
!
dpod 2/0/30
!
dpod 2/0/31
!
dpod 2/0/32
!
dpod 2/0/33
!
dpod 2/0/34
!
dpod 2/0/35
!
dpod 2/0/36
!
dpod 2/0/37
!
dpod 2/0/38
!
dpod 2/0/39
!
dpod 2/0/40
!
dpod 2/0/41
!
dpod 2/0/42
!
dpod 2/0/43
!
dpod 2/0/44
!
dpod 2/0/45
!
dpod 2/0/46
!
dpod 2/0/47
!
dpod 2/0/48
!
dpod 2/0/49
!
dpod 2/0/50
!
dpod 2/0/51
!
dpod 2
chassis-name VDX6740
host-name sw0
!
fabric route mcast rbridge-id 2
ip route 0.0.0.0/0 chassis-name VDX6740
switch-attributes host-name sw0
system-monitor fan threshold marginal-threshold 1 down-threshold 2
system-monitor fan alert state removed action raslog
system-monitor power threshold marginal-threshold 1 down-threshold 2
system-monitor power alert state removed action raslog
system-monitor temp threshold marginal-threshold 1 down-threshold 2
system-monitor cid-card threshold marginal-threshold 1 down-threshold 2
system-monitor cid-card alert state none action none
system-monitor sfp alert state none action none
system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0
system-monitor MM threshold marginal-threshold 1 down-threshold 0
system-monitor LineCard threshold marginal-threshold 1 down-threshold 2
system-monitor LineCard alert state none action none
system-monitor SFM threshold marginal-threshold 1 down-threshold 2
no protocol vrrp
no protocol fabric-map default
fcoe-enodes 0
Management 2/0
no tcp burstrate
ip icmp unreachable
ip icmp echo-reply
no ip address dhcp
ip address 10.76.47.5/22
ipv6 icmpv6 unreachable
ipv6 icmpv6 echo-reply
no ipv6 address autoconfig
no ipv6 address TenGigabitEthernet 2/0/1
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/2
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/3
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/4
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/5
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/6
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/7
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/8
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/9
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/10
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/11
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/12
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/13
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/14
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/15
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/16
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/17
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/18
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/19
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/20
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/21
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/22
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/23
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/24
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/25
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/26
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/27
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/28
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/29
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/30
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/31
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/32
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/33
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/34
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/35
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/36
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/37
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/38
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/39
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/40
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/41
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/42
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/43
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/44
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/45
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/46
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/47
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/48
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/49
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/50
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/51
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/52
fabric isl enable
fabric trunk enable
no show running-config
diag post rbridge-id fsb enable
dpod 2/0/1
!
dpod 2/0/2
!
dpod 2/0/3
!
dpod 2/0/4
!
dpod 2/0/5
!
dpod 2/0/6
!
dpod 2/0/7
!
dpod 2/0/8
!
dpod 2/0/9
!
dpod 2/0/10
!
dpod 2/0/11
!
dpod 2/0/12
!
dpod 2/0/13
!
dpod 2/0/14
!
dpod 2/0/15
!
dpod 2/0/16
!
dpod 2/0/17
!
dpod 2/0/18
!
dpod 2/0/19
!
dpod 2/0/20
!
dpod 2/0/21
!
dpod 2/0/22
!
dpod 2/0/23
!
dpod 2/0/24
!
dpod 2/0/25
!
dpod 2/0/26
!
dpod 2/0/27
!
dpod 2/0/28
!
dpod 2/0/29
!
dpod 2/0/30
!
dpod 2/0/31
!
dpod 2/0/32
!
dpod 2/0/33
!
dpod 2/0/34
!
dpod 2/0/35
!
dpod 2/0/36
!
dpod 2/0/37
!
dpod 2/0/38
!
dpod 2/0/39
!
dpod 2/0/40
!
dpod 2/0/41
!
dpod 2/0/42
!
dpod 2/0/43
!
dpod 2/0/44
!
dpod 2/0/45
!
dpod 2/0/46
!
dpod 2/0/47
!
dpod 2/0/48
!
dpod 2/0/49
!
dpod 2/0/50
!
dpod 2/0/51
!
dpod raslog console INFO
logging auditlog class SECURITY
logging auditlog class CONFIGURATION
logging auditlog class FIRMWARE
logging syslog-facility local LOG_LOCAL7
logging syslog-client localip MM_IP
switch-attributes 2
chassis-name VDX6740
host-name sw0
!
no support autoupload enable
support ffdc
snmp-server contact "Field Support."
snmp-server location "End User Premise."
snmp-server sys-descr "Brocade VDX Switch."
snmp-server community community OrigEquipMfr rw
snmp-server community "Secret C0de" rw
snmp-server community common
snmp-server community private rw
snmp-server community public
snmp-server user snmpadmin1 groupname snmpadmin
snmp-server user snmpadmin2 groupname snmpadmin
snmp-server user snmpadmin3 groupname snmpadmin
snmp-server user snmpuser1
snmp-server user snmpuser2
snmp-server user snmpuser3
line vty
exec-timeout 10
!
zoning enabled-configuration cfg-name ""
zoning enabled-configuration default-zone-access allaccess
zoning enabled-configuration cfg-action cfg-save
role name admin desc Administrator
role name user desc User
aaa authentication login local
aaa accounting exec default start-stop none
aaa accounting commands default start-stop none
service admin password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role admin desc Administrator
username user password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role user desc User
cee-map default
precedence 1
priority-group-table 1 weight 40 pfc on
priority-group-table 15.0 pfc off
priority-group-table 15.1 pfc off
priority-group-table 15.2 pfc off
priority-group-table 15.3 pfc off
priority-group-table 15.4 pfc off
priority-group-table 15.5 pfc off
priority-group-table 15.6 pfc off
priority-group-table 15.7 pfc off
priority-group-table 2 weight 60 pfc off
priority-table 2 2 2 1 2 2 2 15.0
remap fabric-priority priority 0
remap lossless-priority priority default
vlan 1002
priority 3
virtual-fabric 128
fcmap 0E:FC:00
max-enodes 0
enodes-config local
advertisement interval 8000
keep-alive timeout
!
map default
fabric-map default
cee-map Vlan 1
!
fabric route mcast rbridge-id 2
!
protocol lldp
advertise Brocade-VDX-VCS 100
!
vlan dot1q tag native
port-profile switchport
switchport mode trunk
switchport trunk allowed vlan switchport
switchport mode trunk
switchport trunk native-vlan default
port-profile 2
ip route 0.0.0.0/0 chassis-name VDX6740
switch-attributes host-name sw0
system-monitor fan threshold marginal-threshold 1 down-threshold 2
system-monitor fan alert state removed action raslog
system-monitor power threshold marginal-threshold 1 down-threshold 2
system-monitor power alert state removed action raslog
system-monitor temp threshold marginal-threshold 1 down-threshold 2
system-monitor cid-card threshold marginal-threshold 1 down-threshold 2
system-monitor cid-card alert state none action none
system-monitor sfp alert state none action none
system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0
system-monitor MM threshold marginal-threshold 1 down-threshold 0
system-monitor LineCard threshold marginal-threshold 1 down-threshold 2
system-monitor LineCard alert state none action none
system-monitor SFM threshold marginal-threshold 1 down-threshold 2
no protocol vrrp
no protocol fabric-map default
fcoe-enodes 0
Management 2/0
no tcp burstrate
ip icmp unreachable
ip icmp echo-reply
no ip address dhcp
ip address 10.76.47.5/22
ipv6 icmpv6 unreachable
ipv6 icmpv6 echo-reply
no ipv6 address autoconfig
no ipv6 address TenGigabitEthernet 2/0/1
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/2
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/3
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/4
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/5
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/6
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/7
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/8
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/9
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/10
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/11
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/12
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/13
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/14
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/15
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/16
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/17
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/18
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/19
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/20
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/21
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/22
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/23
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/24
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/25
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/26
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/27
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/28
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/29
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/30
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/31
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/32
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/33
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/34
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/35
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/36
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/37
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/38
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/39
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/40
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/41
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/42
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/43
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/44
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/45
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/46
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/47
fabric isl enable
fabric trunk enable
no TenGigabitEthernet 2/0/48
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/49
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/50
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/51
fabric isl enable
fabric trunk enable
no FortyGigabitEthernet 2/0/52
fabric isl enable
fabric trunk enable
no show sfp
Linecard Port Type Breakout Speed
------- ------- ------- ------- -------
0 49 QSFP 1x40G 40G
0 50 QSFP 1x40G 40G
0 51 QSFP 1x40G 40G
0 52 QSFP 1x40G 40G
0 1 SFP n/a 10G
0 2 SFP n/a 10G
0 3 SFP n/a 10G
0 4 SFP n/a 10G
0 5 SFP n/a 10G
0 6 SFP n/a 10G
0 7 SFP n/a 10G
0 8 SFP n/a 10G
0 9 SFP n/a 10G
0 10 SFP n/a 10G
0 11 SFP n/a 10G
0 12 SFP n/a 10G
0 13 SFP n/a 10G
0 14 SFP n/a 10G
0 15 SFP n/a 10G
0 16 SFP n/a 10G
0 17 SFP n/a 10G
0 18 SFP n/a 10G
0 19 SFP n/a 10G
0 20 SFP n/a 10G
0 21 SFP n/a 10G
0 22 SFP n/a 10G
0 23 SFP n/a 10G
0 24 SFP n/a 10G
0 25 SFP n/a 10G
0 26 SFP n/a 10G
0 27 SFP n/a 10G
0 28 SFP n/a 10G
0 29 SFP n/a 10G
0 30 SFP n/a 10G
0 31 SFP n/a 10G
0 32 SFP n/a 10G
0 33 SFP n/a 10G
0 34 SFP n/a 10G
0 35 SFP n/a 10G
0 36 SFP n/a 10G
0 37 SFP n/a 10G
0 38 SFP n/a 10G
0 39 SFP n/a 10G
0 40 SFP n/a 10G
0 41 SFP n/a 10G
0 42 SFP n/a 10G
0 43 SFP n/a 10G
0 44 SFP n/a 10G
0 45 SFP n/a 10G
0 46 SFP n/a 10G
0 47 SFP n/a 10G
0 48 SFP n/a show startup-db
no fsb enable
no support autoupload enable
no support ffdc
no service password-encryption
no vlan dot1q tag show system
Stack MAC : -- UNIT 0 --
Unit Name : sw0
Switch Status : Online
Hardware Rev : 131.7
TengigabitEthernet Port(s) : 48
FortyGigabitEthernet Port(s) : 4
Up Time : up 0:53
Current Time : 13:23:54 GMT
NOS Version : 4.1.3b
Jumbo Capable : yes
Burned In MAC : IP : 10.76.47.5
Management Port Status : UP
-- Power Supplies --
PS1 is OK
PS2 is OK
-- Fan Status --
Fan 1 is Ok, speed is 2887 RPM
Fan 2 is Ok, speed is 2863 show udld
UDLD Global Information
Admin State: No UDLD Protocol
UDLD hello time: 500 milliseconds
UDLD timeout: 2500 show users
**USER Username Role Host IP Device Time Logged In
2 admin admin 127.0.0.1 Cli 2023-11-08 13:17:44
**LOCKED Username
no locked show vcs
Config Mode : Distributed
VCS Mode : Logical Chassis
VCS ID : 100
VCS GUID : Number of Nodes : 1
Rbridge-Id WWN Management IP VCS Status Fabric Status >10:00:50:EB:1A:76:C9:28* 10.76.47.5 Online Online sw0
Specifications Functional Condition:
F3 - Key Functions Working Cosmetic Condition:
C4 - Used Good Data Sanitization:
S3 - Data Clear
Mpn
N/A Function Tests Physical_Inspection
Passed Powers_On
Passed Functions
Passed Shipping
Tracking information is automatically uploaded to once your order ships.
We ship orders within the contiguous US with FedEx or USPS at our discretion. We use 's shipping calculator for all shipping rates.
PO Box, HI, AK, APO/FPO/DPO, and PR orders must be shipped via USPS. Please contact us or request an adjusted invoice before checking out. Local Pickup
If you have purchased an item and prefer to pick it up, please select “Local Pickup” from the shipping options during checkout. Then please contact us to arrange pickup.
Payment must be made through prior to pickup. Combined Shipping
We can typically provide a 30% shipping discount for multiple purchases that will fit in the same box.
For combined shipping, please click 'Request Total' or send us a message before checking out.
We can then adjust your invoice for combined shipping. Expedited Shipping
In order to guarantee the rates and transit times shown, we must receive your order with its payment cleared by 12:00 PM EST during business days.
Orders placed after 12:00 PM EST will be shipped on the next business day.
Orders placed on weekends or holidays will be shipped the next business day.
Please plan your orders accordingly.
Returns
We strive to be a 5 star seller and hope that you are happy with your purchase.
If there is a problem with your order, please contact us through messages or by phone before leaving response. For items that are tested and working properly:
Our return window for working items listed as "New" or "Used" is 30 days.
If the item is no longer wanted or does not fit, the buyer is responsible for return shipping.
If the item is not working as described, we will work with you on the issue, please contact us to resolve. Please review all product details and sale terms before making a purchase.
![Buy Now Buy Now](buy.gif)