UBB Store

BROCADE VDX 6740 BR-VDX6740-24-F 48-Port 10GbE SFP+4x 40GbE Switch
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
BROCADE VDX 6740 BR-VDX6740-24-F 48-Port 10GbE SFP+4x 40GbE Switch
Price: US $219.99
Listing Grid template example Product Photo Description BROCADE VDX 6740 BR-VDX6740-24-F80-1007295-03 48-Port 10GbE SFP+4x 40GbE Switch

Up for sale is a BROCADE VDX 6740 BR-VDX6740-24-F80-1007295-03 48-Port 10GbE SFP+4x 40GbE Switch . This item has been TESTED, POWERED ON, FACTORY RESET, and all ports and lights are shown to be FULLY FUNCTIONAL. This item is in GOOD physical CONDITION with minor scratches, scrapes, and scuffs from previous usage and item DOES NOT come with a POWER CABLE. NO OTHER accessories are included with this item. Please refer to listing's pictures for more details.

You get exactly what you see in the pictures. Please see the pictures for more details.

The best descriptions are in the pictures. Please see the pictures for a better understanding of the item's do our best to describe each item. If you have any questions, feel free to contact us prior to making a purchase.

Please contact us if you have any issues with your purchase before leaving a review. We try our best to resolve all show Operating System Software

Network Operating System Version: 4.1.3

Copyright (c) 1995-2014 Brocade Communications Systems, Inc.

Firmware name: 4.1.3b

Build Time: 23:54:42 Apr 9, 2015

Install Time: 19:37:14 May 19, 2015

Kernel: 1.0.1

Control Processor: e500mc with 4096 MB of memory

Appl Primary/Secondary 4.1.3b

show Name: BR-VDX6740

switchType: 131

FAN Unit: 1

Time Awake: 0 days

FAN Unit: 2

Time Awake: 0 days

POWER SUPPLY Unit: 1

Factory Part Num: 23-1000043-01

Factory Serial Num:

Time Awake: 0 days

POWER SUPPLY Unit: 2

Factory Part Num: 23-1000043-01

Factory Serial Num:

Time Awake: 0 Unit: 1

Power Consume Factor: 0

Factory Part Num: 40-1000927-06

Factory Serial Num: CPL3806L05L

Manufacture: Day: 18 Month: 12 Year: 14

Update: Day: 28 Month: 12 Year: 2016

Time Alive: 580 days

Time Awake: 0 days

Airflow direction : Port side show cipherset

RADIUS Cipher is not configured

LDAP Cipher is not configured

SSH Cipher is not show cli

autowizard false

complete-on-space false

history 100

idle-timeout 600

ignore-leading-space false

output-file terminal

paginate true

prompt1 \H\M#

prompt2 \H(\m)#

screen-length 24

screen-width 80

service prompt config true

show-defaults false

terminal show dot1x

802.1X Port-Based Authentication: Disabled

PAE Capability: Authenticator Only

Protocol Version: 2

Auth Server: RADIUS

Readiness test timeout: show version history

Sno Date & Time Switch Name Slot PID OS Version

1 Tue May 19 19:35:28 2015 VDX2 0 1752 4.1.3b

2 Thu Feb 5 13:17:54 2015 sw0 0 1817 show Tue May 19 19:33:17 2015

Slot SWITCH/0: Firmware install begins.

[2]: Tue May 19 19:37:47 2015

Slot SWITCH/0: Firmware install ends.

[3]: Tue May 19 19:37:47 2015

Slot SWITCH/0: Firmware starts to swap.

[4]: Tue May 19 19:37:59 2015

Slot SWITCH/0: Firmware is Tue May 19 19:37:59 2015

Slot SWITCH/0: The blade begins to reboot.

[6]: Tue May 19 19:42:55 2015

Slot SWITCH/0: Firmware commit begins.

[7]: Tue May 19 19:44:38 2015

Slot SWITCH/0: Firmware commit ends.

[8]: Tue May 19 19:44:38 2015

Slot SWITCH/0: Firmware is downloaded show global-running-config

no fsb enable

logging raslog console INFO

logging auditlog class SECURITY

logging auditlog class CONFIGURATION

logging auditlog class FIRMWARE

logging syslog-facility local LOG_LOCAL7

logging syslog-client localip MM_IP

no support autoupload enable

support ffdc

snmp-server contact "Field Support."

snmp-server location "End User Premise."

snmp-server sys-descr "Brocade VDX Switch."

snmp-server community community OrigEquipMfr rw

snmp-server community "Secret C0de" rw

snmp-server community common

snmp-server community private rw

snmp-server community public

snmp-server user snmpadmin1 groupname snmpadmin

snmp-server user snmpadmin2 groupname snmpadmin

snmp-server user snmpadmin3 groupname snmpadmin

snmp-server user snmpuser1

snmp-server user snmpuser2

snmp-server user snmpuser3

line vty

exec-timeout 10

!

zoning enabled-configuration cfg-name ""

zoning enabled-configuration default-zone-access allaccess

zoning enabled-configuration cfg-action cfg-save

role name admin desc Administrator

role name user desc User

aaa authentication login local

aaa accounting exec default start-stop none

aaa accounting commands default start-stop none

service admin password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role admin desc Administrator

username user password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role user desc User

cee-map default

precedence 1

priority-group-table 1 weight 40 pfc on

priority-group-table 15.0 pfc off

priority-group-table 15.1 pfc off

priority-group-table 15.2 pfc off

priority-group-table 15.3 pfc off

priority-group-table 15.4 pfc off

priority-group-table 15.5 pfc off

priority-group-table 15.6 pfc off

priority-group-table 15.7 pfc off

priority-group-table 2 weight 60 pfc off

priority-table 2 2 2 1 2 2 2 15.0

remap fabric-priority priority 0

remap lossless-priority priority default

vlan 1002

priority 3

virtual-fabric 128

fcmap 0E:FC:00

max-enodes 0

enodes-config local

advertisement interval 8000

keep-alive timeout

!

map default

fabric-map default

cee-map Vlan 1

!

protocol lldp

advertise Brocade-VDX-VCS 100

!

vlan dot1q tag native

port-profile switchport

switchport mode trunk

switchport trunk allowed vlan switchport

switchport mode trunk

switchport trunk native-vlan default

port-profile show interface Status Mode Speed Type 2/0/49 sfpAbsent -- -- --

Fo 2/0/50 sfpAbsent -- -- --

Fo 2/0/51 sfpAbsent -- -- --

Fo 2/0/52 sfpAbsent -- -- --

Te 2/0/1 sfpAbsent -- -- --

Te 2/0/2 sfpAbsent -- -- --

Te 2/0/3 sfpAbsent -- -- --

Te 2/0/4 sfpAbsent -- -- --

Te 2/0/5 sfpAbsent -- -- --

Te 2/0/6 sfpAbsent -- -- --

Te 2/0/7 sfpAbsent -- -- --

Te 2/0/8 sfpAbsent -- -- --

Te 2/0/9 sfpAbsent -- -- --

Te 2/0/10 sfpAbsent -- -- --

Te 2/0/11 sfpAbsent -- -- --

Te 2/0/12 sfpAbsent -- -- --

Te 2/0/13 sfpAbsent -- -- --

Te 2/0/14 sfpAbsent -- -- --

Te 2/0/15 sfpAbsent -- -- --

Te 2/0/16 sfpAbsent -- -- --

Te 2/0/17 sfpAbsent -- -- --

Te 2/0/18 sfpAbsent -- -- --

Te 2/0/19 sfpAbsent -- -- --

Te 2/0/20 sfpAbsent -- -- --

Te 2/0/21 sfpAbsent -- -- --

Te 2/0/22 sfpAbsent -- -- --

Te 2/0/23 sfpAbsent -- -- --

Te 2/0/24 sfpAbsent -- -- --

Te 2/0/25 sfpAbsent -- -- --

Te 2/0/26 sfpAbsent -- -- --

Te 2/0/27 sfpAbsent -- -- --

Te 2/0/28 sfpAbsent -- -- --

Te 2/0/29 sfpAbsent -- -- --

Te 2/0/30 sfpAbsent -- -- --

Te 2/0/31 sfpAbsent -- -- --

Te 2/0/32 sfpAbsent -- -- --

Te 2/0/33 sfpAbsent -- -- --

Te 2/0/34 sfpAbsent -- -- --

Te 2/0/35 sfpAbsent -- -- --

Te 2/0/36 sfpAbsent -- -- --

Te 2/0/37 sfpAbsent -- -- --

Te 2/0/38 sfpAbsent -- -- --

Te 2/0/39 sfpAbsent -- -- --

Te 2/0/40 sfpAbsent -- -- --

Te 2/0/41 sfpAbsent -- -- --

Te 2/0/42 sfpAbsent -- -- --

Te 2/0/43 sfpAbsent -- -- --

Te 2/0/44 sfpAbsent -- -- --

Te 2/0/45 sfpAbsent -- -- --

Te 2/0/46 sfpAbsent -- -- --

Te 2/0/47 sfpAbsent -- -- --

Te 2/0/48 sfpAbsent -- -- show 1 DESCR:Chassis Fan module

PN:N/A 2 DESCR:Chassis Fan module

PN:N/A SUPPLY 1 DESCR:Chassis PS module

PN:23-1000043-01 SUPPLY 2 DESCR:Chassis PS module

PN:23-1000043-01 SN:N/A

NAME: Chassis DESCR:System Chassis

SID:BR-VDX6740 show 10G Port Upgrade license

License has expired

Feature name:PORT_10G_UPGRADE

LICENSE IS INVALID

Capacity: 40G Port Upgrade license

License has expired

Feature name:PORT_40G_UPGRADE

LICENSE IS INVALID

Capacity: show local-running-config

diag post rbridge-id 2/0/1

!

dpod 2/0/2

!

dpod 2/0/3

!

dpod 2/0/4

!

dpod 2/0/5

!

dpod 2/0/6

!

dpod 2/0/7

!

dpod 2/0/8

!

dpod 2/0/9

!

dpod 2/0/10

!

dpod 2/0/11

!

dpod 2/0/12

!

dpod 2/0/13

!

dpod 2/0/14

!

dpod 2/0/15

!

dpod 2/0/16

!

dpod 2/0/17

!

dpod 2/0/18

!

dpod 2/0/19

!

dpod 2/0/20

!

dpod 2/0/21

!

dpod 2/0/22

!

dpod 2/0/23

!

dpod 2/0/24

!

dpod 2/0/25

!

dpod 2/0/26

!

dpod 2/0/27

!

dpod 2/0/28

!

dpod 2/0/29

!

dpod 2/0/30

!

dpod 2/0/31

!

dpod 2/0/32

!

dpod 2/0/33

!

dpod 2/0/34

!

dpod 2/0/35

!

dpod 2/0/36

!

dpod 2/0/37

!

dpod 2/0/38

!

dpod 2/0/39

!

dpod 2/0/40

!

dpod 2/0/41

!

dpod 2/0/42

!

dpod 2/0/43

!

dpod 2/0/44

!

dpod 2/0/45

!

dpod 2/0/46

!

dpod 2/0/47

!

dpod 2/0/48

!

dpod 2/0/49

!

dpod 2/0/50

!

dpod 2/0/51

!

dpod 2

chassis-name VDX6740

host-name sw0

!

fabric route mcast rbridge-id 2

ip route 0.0.0.0/0 chassis-name VDX6740

switch-attributes host-name sw0

system-monitor fan threshold marginal-threshold 1 down-threshold 2

system-monitor fan alert state removed action raslog

system-monitor power threshold marginal-threshold 1 down-threshold 2

system-monitor power alert state removed action raslog

system-monitor temp threshold marginal-threshold 1 down-threshold 2

system-monitor cid-card threshold marginal-threshold 1 down-threshold 2

system-monitor cid-card alert state none action none

system-monitor sfp alert state none action none

system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0

system-monitor MM threshold marginal-threshold 1 down-threshold 0

system-monitor LineCard threshold marginal-threshold 1 down-threshold 2

system-monitor LineCard alert state none action none

system-monitor SFM threshold marginal-threshold 1 down-threshold 2

no protocol vrrp

no protocol fabric-map default

fcoe-enodes 0

Management 2/0

no tcp burstrate

ip icmp unreachable

ip icmp echo-reply

no ip address dhcp

ip address 10.76.47.5/22

ipv6 icmpv6 unreachable

ipv6 icmpv6 echo-reply

no ipv6 address autoconfig

no ipv6 address TenGigabitEthernet 2/0/1

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/2

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/3

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/4

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/5

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/6

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/7

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/8

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/9

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/10

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/11

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/12

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/13

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/14

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/15

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/16

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/17

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/18

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/19

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/20

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/21

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/22

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/23

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/24

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/25

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/26

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/27

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/28

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/29

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/30

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/31

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/32

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/33

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/34

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/35

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/36

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/37

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/38

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/39

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/40

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/41

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/42

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/43

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/44

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/45

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/46

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/47

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/48

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/49

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/50

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/51

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/52

fabric isl enable

fabric trunk enable

no show running-config

diag post rbridge-id fsb enable

dpod 2/0/1

!

dpod 2/0/2

!

dpod 2/0/3

!

dpod 2/0/4

!

dpod 2/0/5

!

dpod 2/0/6

!

dpod 2/0/7

!

dpod 2/0/8

!

dpod 2/0/9

!

dpod 2/0/10

!

dpod 2/0/11

!

dpod 2/0/12

!

dpod 2/0/13

!

dpod 2/0/14

!

dpod 2/0/15

!

dpod 2/0/16

!

dpod 2/0/17

!

dpod 2/0/18

!

dpod 2/0/19

!

dpod 2/0/20

!

dpod 2/0/21

!

dpod 2/0/22

!

dpod 2/0/23

!

dpod 2/0/24

!

dpod 2/0/25

!

dpod 2/0/26

!

dpod 2/0/27

!

dpod 2/0/28

!

dpod 2/0/29

!

dpod 2/0/30

!

dpod 2/0/31

!

dpod 2/0/32

!

dpod 2/0/33

!

dpod 2/0/34

!

dpod 2/0/35

!

dpod 2/0/36

!

dpod 2/0/37

!

dpod 2/0/38

!

dpod 2/0/39

!

dpod 2/0/40

!

dpod 2/0/41

!

dpod 2/0/42

!

dpod 2/0/43

!

dpod 2/0/44

!

dpod 2/0/45

!

dpod 2/0/46

!

dpod 2/0/47

!

dpod 2/0/48

!

dpod 2/0/49

!

dpod 2/0/50

!

dpod 2/0/51

!

dpod raslog console INFO

logging auditlog class SECURITY

logging auditlog class CONFIGURATION

logging auditlog class FIRMWARE

logging syslog-facility local LOG_LOCAL7

logging syslog-client localip MM_IP

switch-attributes 2

chassis-name VDX6740

host-name sw0

!

no support autoupload enable

support ffdc

snmp-server contact "Field Support."

snmp-server location "End User Premise."

snmp-server sys-descr "Brocade VDX Switch."

snmp-server community community OrigEquipMfr rw

snmp-server community "Secret C0de" rw

snmp-server community common

snmp-server community private rw

snmp-server community public

snmp-server user snmpadmin1 groupname snmpadmin

snmp-server user snmpadmin2 groupname snmpadmin

snmp-server user snmpadmin3 groupname snmpadmin

snmp-server user snmpuser1

snmp-server user snmpuser2

snmp-server user snmpuser3

line vty

exec-timeout 10

!

zoning enabled-configuration cfg-name ""

zoning enabled-configuration default-zone-access allaccess

zoning enabled-configuration cfg-action cfg-save

role name admin desc Administrator

role name user desc User

aaa authentication login local

aaa accounting exec default start-stop none

aaa accounting commands default start-stop none

service admin password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role admin desc Administrator

username user password "BwrsDbB+tABWGWpINOVKoQ==\" encryption-level 7 role user desc User

cee-map default

precedence 1

priority-group-table 1 weight 40 pfc on

priority-group-table 15.0 pfc off

priority-group-table 15.1 pfc off

priority-group-table 15.2 pfc off

priority-group-table 15.3 pfc off

priority-group-table 15.4 pfc off

priority-group-table 15.5 pfc off

priority-group-table 15.6 pfc off

priority-group-table 15.7 pfc off

priority-group-table 2 weight 60 pfc off

priority-table 2 2 2 1 2 2 2 15.0

remap fabric-priority priority 0

remap lossless-priority priority default

vlan 1002

priority 3

virtual-fabric 128

fcmap 0E:FC:00

max-enodes 0

enodes-config local

advertisement interval 8000

keep-alive timeout

!

map default

fabric-map default

cee-map Vlan 1

!

fabric route mcast rbridge-id 2

!

protocol lldp

advertise Brocade-VDX-VCS 100

!

vlan dot1q tag native

port-profile switchport

switchport mode trunk

switchport trunk allowed vlan switchport

switchport mode trunk

switchport trunk native-vlan default

port-profile 2

ip route 0.0.0.0/0 chassis-name VDX6740

switch-attributes host-name sw0

system-monitor fan threshold marginal-threshold 1 down-threshold 2

system-monitor fan alert state removed action raslog

system-monitor power threshold marginal-threshold 1 down-threshold 2

system-monitor power alert state removed action raslog

system-monitor temp threshold marginal-threshold 1 down-threshold 2

system-monitor cid-card threshold marginal-threshold 1 down-threshold 2

system-monitor cid-card alert state none action none

system-monitor sfp alert state none action none

system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0

system-monitor MM threshold marginal-threshold 1 down-threshold 0

system-monitor LineCard threshold marginal-threshold 1 down-threshold 2

system-monitor LineCard alert state none action none

system-monitor SFM threshold marginal-threshold 1 down-threshold 2

no protocol vrrp

no protocol fabric-map default

fcoe-enodes 0

Management 2/0

no tcp burstrate

ip icmp unreachable

ip icmp echo-reply

no ip address dhcp

ip address 10.76.47.5/22

ipv6 icmpv6 unreachable

ipv6 icmpv6 echo-reply

no ipv6 address autoconfig

no ipv6 address TenGigabitEthernet 2/0/1

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/2

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/3

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/4

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/5

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/6

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/7

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/8

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/9

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/10

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/11

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/12

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/13

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/14

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/15

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/16

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/17

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/18

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/19

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/20

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/21

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/22

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/23

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/24

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/25

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/26

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/27

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/28

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/29

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/30

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/31

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/32

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/33

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/34

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/35

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/36

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/37

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/38

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/39

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/40

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/41

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/42

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/43

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/44

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/45

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/46

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/47

fabric isl enable

fabric trunk enable

no TenGigabitEthernet 2/0/48

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/49

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/50

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/51

fabric isl enable

fabric trunk enable

no FortyGigabitEthernet 2/0/52

fabric isl enable

fabric trunk enable

no show sfp

Linecard Port Type Breakout Speed

------- ------- ------- ------- -------

0 49 QSFP 1x40G 40G

0 50 QSFP 1x40G 40G

0 51 QSFP 1x40G 40G

0 52 QSFP 1x40G 40G

0 1 SFP n/a 10G

0 2 SFP n/a 10G

0 3 SFP n/a 10G

0 4 SFP n/a 10G

0 5 SFP n/a 10G

0 6 SFP n/a 10G

0 7 SFP n/a 10G

0 8 SFP n/a 10G

0 9 SFP n/a 10G

0 10 SFP n/a 10G

0 11 SFP n/a 10G

0 12 SFP n/a 10G

0 13 SFP n/a 10G

0 14 SFP n/a 10G

0 15 SFP n/a 10G

0 16 SFP n/a 10G

0 17 SFP n/a 10G

0 18 SFP n/a 10G

0 19 SFP n/a 10G

0 20 SFP n/a 10G

0 21 SFP n/a 10G

0 22 SFP n/a 10G

0 23 SFP n/a 10G

0 24 SFP n/a 10G

0 25 SFP n/a 10G

0 26 SFP n/a 10G

0 27 SFP n/a 10G

0 28 SFP n/a 10G

0 29 SFP n/a 10G

0 30 SFP n/a 10G

0 31 SFP n/a 10G

0 32 SFP n/a 10G

0 33 SFP n/a 10G

0 34 SFP n/a 10G

0 35 SFP n/a 10G

0 36 SFP n/a 10G

0 37 SFP n/a 10G

0 38 SFP n/a 10G

0 39 SFP n/a 10G

0 40 SFP n/a 10G

0 41 SFP n/a 10G

0 42 SFP n/a 10G

0 43 SFP n/a 10G

0 44 SFP n/a 10G

0 45 SFP n/a 10G

0 46 SFP n/a 10G

0 47 SFP n/a 10G

0 48 SFP n/a show startup-db

no fsb enable

no support autoupload enable

no support ffdc

no service password-encryption

no vlan dot1q tag show system

Stack MAC : -- UNIT 0 --

Unit Name : sw0

Switch Status : Online

Hardware Rev : 131.7

TengigabitEthernet Port(s) : 48

FortyGigabitEthernet Port(s) : 4

Up Time : up 0:53

Current Time : 13:23:54 GMT

NOS Version : 4.1.3b

Jumbo Capable : yes

Burned In MAC : IP : 10.76.47.5

Management Port Status : UP

-- Power Supplies --

PS1 is OK

PS2 is OK

-- Fan Status --

Fan 1 is Ok, speed is 2887 RPM

Fan 2 is Ok, speed is 2863 show udld

UDLD Global Information

Admin State: No UDLD Protocol

UDLD hello time: 500 milliseconds

UDLD timeout: 2500 show users

**USER Username Role Host IP Device Time Logged In

2 admin admin 127.0.0.1 Cli 2023-11-08 13:17:44

**LOCKED Username

no locked show vcs

Config Mode : Distributed

VCS Mode : Logical Chassis

VCS ID : 100

VCS GUID : Number of Nodes : 1

Rbridge-Id WWN Management IP VCS Status Fabric Status >10:00:50:EB:1A:76:C9:28* 10.76.47.5 Online Online sw0

Specifications Functional Condition:
F3 - Key Functions Working Cosmetic Condition:
C4 - Used Good Data Sanitization:
S3 - Data Clear
Mpn
N/A Function Tests Physical_Inspection
Passed Powers_On
Passed Functions
Passed Shipping


Tracking information is automatically uploaded to once your order ships.
We ship orders within the contiguous US with FedEx or USPS at our discretion. We use 's shipping calculator for all shipping rates.
PO Box, HI, AK, APO/FPO/DPO, and PR orders must be shipped via USPS. Please contact us or request an adjusted invoice before checking out. Local Pickup
If you have purchased an item and prefer to pick it up, please select “Local Pickup” from the shipping options during checkout. Then please contact us to arrange pickup.
Payment must be made through prior to pickup. Combined Shipping
We can typically provide a 30% shipping discount for multiple purchases that will fit in the same box.
For combined shipping, please click 'Request Total' or send us a message before checking out.
We can then adjust your invoice for combined shipping. Expedited Shipping
In order to guarantee the rates and transit times shown, we must receive your order with its payment cleared by 12:00 PM EST during business days.
Orders placed after 12:00 PM EST will be shipped on the next business day.
Orders placed on weekends or holidays will be shipped the next business day.
Please plan your orders accordingly.

Returns


We strive to be a 5 star seller and hope that you are happy with your purchase.
If there is a problem with your order, please contact us through messages or by phone before leaving response. For items that are tested and working properly:
Our return window for working items listed as "New" or "Used" is 30 days.
If the item is no longer wanted or does not fit, the buyer is responsible for return shipping.
If the item is not working as described, we will work with you on the issue, please contact us to resolve. Please review all product details and sale terms before making a purchase.



Buy Now